Filter checks

Passed  
Failed  
Warning  
Not Run  
   

Navigation

Model Advisor
1 By Product
1.1 Simulink
2 By Task
2.1 Code Generation Efficiency
2.2 Data Transfer Efficiency
2.3 Managing Data Store Memory Blocks
2.4 Managing Library Links And Variants
2.5 Model Referencing
2.6 Modeling Signals and Parameters using Buses
2.7 Modeling Single-Precision Systems
2.8 Simulation Accuracy
2.9 Simulation Runtime Accuracy Diagnostics
2.10 Simulink Model File Integrity
2.11 Upgrading to the Current Simulink Version

View

Scroll to top
Show check details
Model Advisor Report - k1visbs.mdl
Simulink version: 8.5 Model version: 1.161
System: k1visbs/BS Current run: 07-Dec-2016 10:34:34
4 items with a timestamp different than 07-Dec-2016 10:34:34  

Run Summary
Pass Fail Warning Not Run Total
   11    1    5    41 58


Model Advisor


    1 By Product  0  0  0  33


        1.1 Simulink  0  0  0  33


    2 By Task  11  1  5  8


        2.1 Code Generation Efficiency  0  0  1  0


  Check optimization settings

You should turn on the following optimization(s):

  • Inline parameters



  •         2.2 Data Transfer Efficiency  0  0  0  1


      Check Delay, Unit Delay and Zero-Order Hold blocks for rate transition

    Not Run



            2.3 Managing Data Store Memory Blocks  0  0  1  2


      Check Data Store Memory blocks for multitasking, strong typing, and shadowing issues

    Duplicate data store names checking is not set to 'error'. Duplicate usage of data store names can lead to unintended shadowing of data stores of higher model scope. Consider changing this setting to 'error' on the Data Validity page of the Configuration Parameters dialog box.


      Check data store block sample times for modeling errors

    Not Run


      Check for potential ordering issues involving data store access

    Not Run



            2.4 Managing Library Links And Variants  4  0  1  0

            2.5 Model Referencing  3  0  1  1


      Check diagnostic settings ignored during accelerated model reference simulation

    The configuration parameter settings passed the check.


      Check for parameter tunability information ignored for referenced models

    Passed


      Check for implicit signal resolution

    Passed


      Check bus usage

    Not Run


      Check root model Inport block specifications

    This check is only supported at the model level. To run this analysis, please open the model advisor from the top level of the model instead of the subsystem level and start the analysis.



            2.6 Modeling Signals and Parameters using Buses  0  1  0  2


      Check for optimal bus virtuality

    Abnormal exit: Failed to load library 'dsparch4' referenced by 'k1visbs/BS/F0/WD/F0AC/BANDLIM/ACC_H3/Digital Filter0'


      Check for partial structure parameter usage with bus signals

    Not Run


      Check bus usage

    Not Run



            2.7 Modeling Single-Precision Systems  0  0  0  1


      Identify questionable operations for strict single-precision design

    Not Run



            2.8 Simulation Accuracy  0  0  0  1


      Check for non-continuous signals driving derivative ports

    Not Run



            2.9 Simulation Runtime Accuracy Diagnostics  2  0  0  0


      Runtime diagnostics for S-functions

    Passed


      Check if Read/Write diagnostics are enabled for Data Store blocks

    Passed



            2.10 Simulink Model File Integrity  2  0  0  0

            2.11 Upgrading to the Current Simulink Version  0  0  1  0